Termite and rodent resistant wires and cables

Zhejiang Hongce Cable Co., Ltd. specializes in high-performance termite and rodent-proof cables (FY, FSH, FSY series). Engineered with a robust dual-defense system, our cables combine eco-friendly, non-toxic chemical repellents with resilient physical barriers, including metallic armoring and high-hardness sheaths. This design effectively deters pests without environmental pollution. Supporting 300V to 35kV, our cables offer exceptional insulation, superior anti-aging properties, and long-term reliability.
Technical Specifications
| Conductor Material | Pure Copper (Cu) / Bare Copper / Tinned Copper (TC) / Aluminum (Al) / Copper Clad Aluminum (CCA) |
| Conductor Class | Class 1 (Solid) / Class 2 (Stranded) / Class 5 (Flexible Conductor) |
| Insulation Layer | Cross-linked Polyethylene (XLPE) / Polyvinyl Chloride (PVC) / Flame-retardant PVC / Low Smoke Zero Halogen (LSZH) / Ethylene Propylene Rubber (EPR) |
| Filler | Flame-retardant PP filling rope / Low-smoke zero-halogen filling / Glass fiber / Ceramic fiber |
| Taping | Halogen-free flame retardant wrapping tape / Aluminum-plastic composite tape / Fiberglass tape / Steel tape |
| Armor | Steel Tape Armoured (STA) / Steel Wire Armoured (SWA) |
| Sheath | Rodent and termite resistant low-smoke zero-halogen polyolefin / flame-retardant PVC / MDPE / HDPE / Nylon (PA) sheath |
| Core Processes for Rodent and Termite Prevention | Chemical Repellent Treatment: Add eco-friendly and non-toxic chemical ant repellents (e.g., Bitrex) Physical Barrier Protection: Shield with metal armor layers Rigid Outer Sheath: Resist rodent gnawing via rigid polymers (Nylon/HDPE) |
| Rated Voltage (U₀/U) | Multiple product series covering 26/35kV to 300/300V |
| Cross-sectional area range | 1.5 mm² – 400 mm² |
| Core configuration | 1 – 5 cores (multi-core control cables can have up to 37 cores) |
| Maximum Operating Temperature of Conductor | 70°C – 105°C(PVC:70–90°C;XLPE/EPR:90–105°C) |
| Bending Radius | 12 – 15D (D refers to the actual outer diameter of the cable) |
Compliance Standards
- ✓IEC 60502-1
- ✓IEC 60228
- ✓RoHS
Overview
In environments where biological hazards pose a significant threat to infrastructure, standard cabling solutions often fall short. Zhejiang Hongce Cable Co., Ltd. proudly introduces our specialized line of Termite-Proof and Rodent-Proof Cables, engineered specifically to withstand the severe challenges of pest-infested areas. Comprising the FY (Termite-Proof), FSH (Rodent-Proof), and FSY (Termite & Rodent-Proof) series, these premium cables are designed to ensure uninterrupted power distribution and seamless signal transmission, preventing costly downtime and infrastructure maintenance. Advanced Dual-Defense Technology At the core of our product’s reliability is a state-of-the-art dual-defense system. Recognizing that mechanical barriers alone are sometimes insufficient, our engineering team has integrated both physical armor and chemical deterrence. Physical Protection: Fortified with Steel Tape Armor (STA) or Steel Wire Armor (SWA), combined with highly durable, high-density polymer outer sheaths such as HDPE or Nylon (PA). These exceptionally hard outer jackets make it practically impossible for rodents to gnaw through. Chemical Deterrence: The outer sheathing incorporates eco-friendly, non-toxic repellents (such as Bitrex) that alter the taste and odor profile of the cable. This successfully deters termites and ants without polluting the surrounding soil or harming the local ecosystem, ensuring true environmental sustainability. Comprehensive Technical Specifications Our expansive product range is built to meet versatile industrial and commercial needs. We offer power cables with rated voltages spanning from 300/300V up to 26/35kV, alongside highly reliable control and instrumentation cables. The conductor options include high-quality pure copper, tinned copper, aluminum, and copper-clad aluminum (CCA), available in Class 1, 2, or 5 flexibility. To guarantee optimal electrical safety and performance across various demanding climates, we provide multiple insulation choices including XLPE, PVC, LSZH, and EPR. The cables support maximum operating temperatures ranging from 70°C to 105°C, and feature a standard bending radius of 12-15D, allowing for flexible installation in complex spatial layouts. Wide Application Scenarios The applications for the FY, FSH, and FSY series are vast. They are the definitive choice for: Underground Utility Systems: Direct burial projects and municipal pipeline networks in termite-prone geographic regions. Agricultural & Forestry Zones: Providing critical infrastructure protection in open rural environments susceptible to wildlife. Mission-Critical Facilities: Indoor environments like data centers, server rooms, and warehouses where unexpected rodent infestation could lead to catastrophic electrical or network failures.
Applications

Underground Pipe Networks and Direct Burial
Direct Burial and Conduit Laying Works of Underground Cables in Areas with Frequent White Phenomenon

Municipal and Residential Facilities
Outdoor wiring systems for residential communities, parks and municipal engineering projects

Agriculture, Forestry, Animal Husbandry and Fishery
Power and control lines vulnerable to wildlife impacts in agricultural and forestry zones

Key Indoor and Outdoor Rodent Prevention Areas
Warehouses, data center computer rooms and other facilities highly vulnerable to rodent infestations